Market Segment
Grid Monitoring & Metering Solutions for Utilities
Frequently Asked Questions
What is PMU / WAMS and how does SATEC support it?
A Phasor Measurement Unit (PMU) provides precisely time-synchronized measurements of voltage and current phasors, frequency and ROCOF from different points on the grid. SATEC PMU platforms (PMU PRO, PM180) feed phasor data to a Phasor Data Concentrator and Wide-Area Monitoring System (WAMS), giving operators real-time visibility of grid dynamics and situational awareness across the network.
Does SATEC support IEC 61850 and digital substations?
Yes. Supported SATEC meters and power quality analyzers integrate into IEC 61850-based substation automation systems, providing electrical measurements, power quality information, status and event data through standardized communication. Selected SATEC models also support dedicated Low-Power Instrument Transformer (LPIT) interfaces, depending on the device and sensor configuration.
What power-quality monitoring does SATEC provide for utilities?
SATEC provides Class A power-quality monitoring (per IEC 61000-4-30) at substations, feeders and network nodes - measuring harmonics, sags/swells, interruptions, unbalance and flicker, and recording waveforms and events for disturbance investigation and national or regional PQ programs.
Can SATEC monitor power-generation facilities?
Yes. At conventional generation facilities, SATEC monitors generator output, auxiliary consumption, active/reactive power, power quality, event recording and grid interconnection. For independent power producers (IPPs), it also supports revenue/check metering, energy export, PPA-related accounting and point-of-common-coupling (PCC) monitoring.
Does SATEC provide utility revenue and settlement metering?
Yes. SATEC offers high-accuracy revenue metering solutions, including EM720 and selected PRO Series meters, for utility billing, settlement, check metering and boundary metering at substations, generation interconnections and large customer installations. Accuracy classes, approvals and measurement configurations must be selected according to the applicable regulatory, utility and project requirements.
Modern power systems require visibility across transmission networks, distribution grids, substations and grid-connection points. Utilities need accurate, time-synchronized and standards-based measurements to monitor system conditions, investigate disturbances, verify energy flows and integrate new digital infrastructure.
SATEC provides utility-grade metering, power-quality analysis, synchrophasor measurement, disturbance recording and communication solutions for grid operators — from individual substations to wide-area monitoring architectures and centralized SCADA or energy-management systems.
From Synchronized Grid Visibility to Post-Event Analysis
A utility monitoring platform should provide more than steady-state measurements. Depending on the application, utilities may require synchronized phasors, frequency and ROCOF, Class A power-quality statistics, waveform and event recording, revenue energy registers and status/I/O information. Combining these data sources helps operators understand both normal grid behavior and what happened during a disturbance.

Utility Applications
Who We Serve
Transmission System Operators
PMU, WAMS, grid stability, disturbances and network PQ
Distribution Utilities
Substations, feeders, distributed generation and PQ monitoring
Power Generation Facilities
Generator output, auxiliary loads, disturbances and plant export
Independent Power Producers
PPA energy accounting, settlement, PCC power quality and grid compliance monitoring

PMU / WAMS & Disturbance Recording
Phasor Measurement Units provide precisely time-synchronized measurements from multiple grid locations. SATEC PMU platforms provide synchronized voltage and current phasors, frequency and ROCOF for wide-area monitoring, differentiating SATEC from ordinary multifunction-meter suppliers.
At substations and critical nodes, SATEC Class A analyzers support network PQ monitoring, while advanced platforms such as PM180 add high-resolution waveform/event recording and PMU functionality for post-event analysis — monitoring and analysis, not a replacement for protection relays.
Digital Substations and IEC 61850
Utilities are progressively replacing isolated devices and hardwired interfaces with interoperable digital substation architectures. SATEC devices supporting IEC 61850 provide metering, power-quality and related data as part of the station communication environment. Explore the Digital Substation solution.
Power Generation & IPP Monitoring
SATEC also supports conventional power-generation facilities, with monitoring of generator output, auxiliary consumption, active and reactive power, power quality, event recording and grid interconnection.
For independent power producers (IPPs), SATEC additionally supports revenue and check metering, energy export, PPA-related accounting and point-of-common-coupling (PCC) monitoring.
Core SATEC Solutions for Utilities & Grid
PMU / Wide Area Monitoring — time-synchronized phasors, frequency and ROCOF for WAMS. Learn more
Power Quality Analysis — Class A PQ at substations, feeders and network nodes. Learn more
Digital Substation — IEC 61850-based substation architectures and modernization. Learn more
SCADA Power Monitoring — integrate measurements, status, events and energy into utility SCADA. Learn more
Billing / Revenue Metering — billing, settlement, check and boundary metering. Learn more
Fast Frequency Response — high-resolution frequency and active-power response for grids with inverter-based resources. Learn more
Typical Utility Monitoring Architecture
A typical utility deployment follows the flow: CT/VT or LPIT sensors → SATEC revenue meter / PQ analyzer / PMU / DFR at the substation → station LAN / IEC 61850 / utility protocols → SCADA / PDC / WAMS / PAS / ExpertPower → utility control center, with separate data flows for transmission, distribution and revenue/settlement.
Relevant SATEC Product Families
- PM180 — Class A power quality, disturbance/event recording, PMU and advanced substation monitoring.
- PRO Series — advanced multifunction metering and power-quality with utility communication options.
- EM720 — revenue metering with advanced power-quality functionality for utility/substation applications.
- BFM-DFR / BFM family — multi-circuit monitoring and fault/disturbance recording for dense feeder measurement.
- ExpertPower / PAS — collection, analysis, reporting and centralized monitoring.